Fire dampers
Operation principle of fire dampers
Halton & Flamgard Fire Dampers for Demanding Applications

Fire dampers are used to prevent the spread of fire and smoke through the ventilation systems. In the event of a fire, the damper will automatically close, preventing the passage of flames and smoke through the ventilation ducts.
Click the picture to see the basic operation principle of a motorized fire damper.

  • High-quality fire dampers specifically designed for most demanding applications with a long experience
  • Over 100,000 fire dampers manufactured for demanding applications
  • Quality recognized by major classification societies and owners worldwide
  • Selected products ATEX approved, g-shock and vibration tested and SIL 2 rated

NFD-01 Fire Damper for Nuclear Applications

Contact us for more information

NFD-01-ICB Fire Damper for Nuclear Applications

Contact us for more information

CFD-01 Fire Damper – A0 (A60), H0(H120) or E120S and BS476 Fire Classifications

Flamgard CFD-01 Fire damper. EN 1366-2 tested for categories ‘E’ Integrity ‘S’ Smoke . Maximum single module size 3100×3100 mm (DNV-GL), 2050×2050 mm (ABS) for A class applications. H class applications are also accommodated at various sizes.

  • Low leakage in accordance with EN 1751 Class 3 and Class C
  • ATEX rated
  • SIL 2 rated to IEC 62508-2:2010
  • NORSOK complaint
CFD-01-ICB – EI120S Insulated fire damper

Flamgard CFD-01-ICB Fire damper. A High Integrity insulated Fire Damper used to prevent the spread of flame, smoke and heat through a HVAC system, in the event of a fire.

  • EN 1366-2 tested for categories ‘E’ Integrity, ‘S’ Smoke, ‘I’ Insulation
  • Low leakage in accordance to BS EN 7151 Class 3 and Class C
  • ATEX rated
CFD-02 – Medium Duty Fire and Smoke Damper

Flamgard CFD-02 Fire and Smoke damper. The damper has been successfully tested in accordance for A Class installations by DNV Lloyds Register of Shipping, MED, USCG-EU MRA.

  • SIL 2 Rated to IEC 62508-2:2010
  • Low leakage in accordance to BS EN 1751 Class 3 and Class C
  • ATEX rated
  • NORSOK complaint
FCE – Fire damper (EI 60 S)

Halton FCE fire dampers are CE-marked according EN 15650:2010 and tested according to EN 1366-2 standard. Halton FCE fire dampers are used as safety-related components in ventilation systems to prevent fire and smoke spreading through ducting.

  • Closed blade leakage to EN 1751,
    Class 3 size >=200×200 mm
  • Casing leakage to EN 1751, Class C
  • SIL 2 safety assessment certificate available for the damper on specific terms
  • Available as ATEX certified
FDB2 – A0(A60) Fire and Gas Damper

Halton FDB2 fire dampers are type-approved by the most recognized classification societies: class A0 without insulation, A15-A60 when suitably insulated. Blades contain silicone seals (effective up to 300 ºC) for low leakage in normal conditions and thermal expansion graphite seals (effective from 150 ºC) to increase tightness even up to 50% in a case of fire.

  • Closed blade leakage to EN 1751,
    Class 1 to 3 depending on size
  • Casing leakage to EN 1751, Class B
  • SIL 2 safety assessment certificate available for the damper on specific terms
  • Available as ATEX certified by order
FDO – A0(A60) Fire and Gas Damper

Halton FDO fire dampers are type-approved class A0 – A60 fire damper when suitably insulated. The blade contains seals (effective up to 270 ºC).

  • Closed blade leakage to EN 1751,
    Class 2 to 4 depending on size
  • Casing leakage to EN 1751, Class C
  • SIL 2 safety assessment certificate available for the damper on specific terms
  • Available as ATEX certified by order
FDL – A0(A60) Fire Damper

Halton FDL fire dampers are type-approved class A0 without insulation, A15-A60 when suitably insulated. Blades with intumescent seals.

  • Closed blade leakage to EN 1751,
    Class 1 to 2 depending on size
  • Casing leakage to EN 1751, Class B
  • SIL 2 safety assessment certificate available for the damper on specific terms
  • Available as ATEX certified by order
FDA – A0(A60) Fire and Gas Damper

Halton FDA fire dampers are type-approved by most recognized classification societies: A0 without insulation, A-15 to A-60 when suitably insulated. Blades contain stainless steel spring seals for low leakage in normal conditions and thermal expansion graphite seals (effective from 150ºC) to seal the damper in case of fire. Silicon sealing as an option.

  • Closed blade leakage to EN 1751,
    Class 3 for size > 300×300 mm and for size > 200×200 mm (silicon seals)
  • Casing leakage to EN 1751, Class C
  • SIL 2 safety assessment certificate available for the damper on specific terms
  • Available as ATEX certified by order
FDH – H0(120) Fire and Gas Damper

Halton FDH fire dampers are type-approved by the most recognized classification societies: class H0(H120) fire damper when suitably insulated. Pre-insulated H0(H60) with ceramic wool at the factory. H0(H120) with additional insulation on site. Blades insulated with ceramic wool.

  • Closed blade leakage to EN 1751,
    Class 3 for size > 300×300 mm
  • Casing leakage to EN 1751, Class C
  • SIL 2 safety assessment certificate available for the damper on specific terms
  • Available as ATEX certified by order

Not sure which product is a perfect match for your need?